RamSan-325/325c User’s Manual - 114 -
Name power-state-notif
Description The power state has changed
Includes Message
Power State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState N/A
1 error Voltage levels are dangerously low; the system
may be powered off.
2 warn Voltage and/or current levels are below
specification.
3 good Voltage and current levels are within specification.
4 warnHigh Voltage and/or current levels are above
specification, or AC power has been lost.
5 errorHigh Voltage and/or current levels are dangerously
high; the system may be powered off.
6 noDevice N/A
7 notMonitored Monitoring has been turned off to suppress
warnings.
Name memory-state-notif
Description The memory state has changed
Includes Message
Memory State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState N/A
1 error N/A
2 warn N/A
3 good The memory has been working properly since
system power on.
4 warnHigh There have been one or more corrected ECC
errors since system power on.
5 errorHigh There have been one or more uncorrected ECC
errors since system power on.
6 noDevice N/A
7 notMonitored Monitoring has been turned off to suppress
warnings.