Texas-memory-systems RamSan-325/325c Uživatelský manuál Strana 91

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 121
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 90
RamSan-325/325c User’s Manual - 87 -
In addition, resetting the controller causes the system to loose the link
temporarily. Reads and writes occurring when the administrator resets
this controller back to “Primary (Active)” state result in errors because the
drives appear to have been removed. TMS does not recommend
configuring an active secondary controller as primary unless no
transmissions are taking place.
Via Web Interface
To change the failover state via the web interface:
Click on the “Fibre Channel Controller” graphic.
Click on the “Controller Setup” tab.
Select from the “Select failover mode” settings.
Click the “Save” button.
Figure 7-4: Failover Setup via Web Interface
Zobrazit stránku 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 120 121

Komentáře k této Příručce

Žádné komentáře