RamSan-325/325c User’s Manual - 116 -
Name fan-state-notif
Description The fan state has changed
Includes Message
Fan State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState N/A
1 error One or more fan channels have stopped;
temperature warnings that will cause the system
to shutdown are imminent.
2 warn Single fans in one or more fan channels have
stopped or are running slowly. There is no
immediate danger, but the fans may need to be
serviced.
3 good All fans are working properly.
4 warnHigh One or more fans are spinning too fast. The
system is in no immediate danger but may need
to be serviced.
5 errorHigh N/A
6 noDevice N/A
7 notMonitored Fan monitoring has been turned off to suppress
warnings.
Name disk-state-notif
Description The disk state has changed
Includes Message
Device Number
Disk State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState N/A
1 error N/A
2 warn N/A
3 good The disk is working properly
4 warnHigh The disk is rebuilding.
5 errorHigh The disk has failed, or is missing from the system.
6 noDevice N/A
7 notMonitored Monitoring has been turned off to suppress
warnings.